SERVICE MANUAL
CONTENTS
1. TECHNICAL CHANGES ····································2
2. PART NAMES AND FUNCTIONS······················6
3. SPECIFICATION·················································6
4. NOISE CRITERIA CURVES·······························7
5. OUTLINES AND DIMENSIONS ·························8
6. WIRING DIAGRAM ············································9
7. REFRIGERANT SYSTEM DIAGRAM··············10
8. PERFORMANCE CURVES ······························11
9. SERVICE FUNCTIONS ····································22
10. TROUBLESHOOTING······································22
11. DISASSEMBLY INSTRUCTIONS·····················29
12. PARTS LIST······················································32
Wireless type
Models
MUH-GA20VB -
MUH-GA25VB -
MUH-GA35VB -
E1
E1
E1
No. OB387
HFC
utilized
R410A
SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS
MUH-GA20VB -
MUH-GA25VB -
MUH-GA35VB -
E1
E1
E1
Indication of
model name
NOTE:
•This manual describes technical data of outdoor units.
•As for indoor units MSC-GA20/GA25/GA35VB - , refer to the service manual OB385.
•As for indoor units MSC-CA20/CA25/CA35VB - , refer to the service manual OB393.
E1
E1
OB387-1.qxp 05.2.21 10:03 AM Page 1
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - MUH-GA35VB

SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································22. PART NAMES AND FUNCTIONS······················63. SPECIFICATION····

Seite 2 - TECHNICAL CHANGES

10REFRIGERANT SYSTEM DIAGRAM7OUTDOOR UNIT(with heat insulator)Refrigerant pipe [ 9.524-way valveDefrostthermistorRT61MufflerOutdoorheatexchangerCapill

Seite 3

11 Piping size O.D : mm Length of connecting pipe : mModelRefrigerant pipingMax. length : m A2025Indoor unitGas 0.43Liquid 0.5 Liquid6.35Gas9.52Out

Seite 4

12MSC-GA20VB - E1MUH-GA20VB - E1 MUH-GA35VB - E1 MSC-GA35VB - E1MUH-GA25VB - E1 MSC-GA25VB - E18.57.87.16.45.85.110.09.28.37.56.86.011.010.09.18.27.46

Seite 5 - 5.Additional charge

138-2.OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENTCOOL operation① Both indoor and outdoor unit are under the same temperature/humidity condition.➁ Ai

Seite 6 - SPECIFICATION

14HEAT operationCondition indoor:Dry bulb temperature 20.0°CWet bulb temperature 14.5°COutdoor:Dry bulb temperature 7,15,20°CWet bulb temperature 6,12

Seite 7 - NOISE CRITERIA CURVES

15MSC-GA20VB - : MUH-GA20VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.70 1.51 0.56 572 2.59 1.45 0.56 601 2.48 1.39 0.56 629 2.39 1.34 0.56

Seite 8 - OUTLINES AND DIMENSIONS

16MSC-GA20VB - : MUH-GA20VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.25 1.26 0.56 701 2.07 1.16 0.56 744 1.99 1.11 0.56 75821 20 2.37 1.04

Seite 9 - WIRING DIAGRAM

17MSC-GA25VB - : MUH-GA25VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 3.11 1.62 0.52 656 2.98 1.55 0.52 689 2.86 1.49 0.52 722 2.76 1.43 0.52

Seite 10 - REFRIGERANT SYSTEM DIAGRAM

18MSC-GA25VB - : MUH-GA25VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 2.60 1.35 0.52 804 2.39 1.24 0.52 853 2.29 1.19 0.52 86921 20 2.73 1.09

Seite 11 - PERFORMANCE CURVES

19MSC-GA35VB - : MUH-GA35VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 4.11 1.97 0.48 872 3.94 1.89 0.48 916 3.78 1.81 0.48 959 3.64 1.75 0.48

Seite 12 - OUTDOOR UNIT

TECHNICAL CHANGES21MUH-A07YV- ➔MUH-GA20VB-1. Indication of capacity has been changed. (BTU base ➔ kw)2. Dimension of outdoor unit has been changed. (7

Seite 13

20MSC-GA35VB - : MUH-GA35VB -E1E1PERFORMANCE DATACOOL operation (230V)21 18 3.43 1.65 0.48 1068 3.15 1.51 0.48 1134 3.03 1.45 0.48 115521 20 3.61 1

Seite 14 - HEAT operation

21MSC-GA20VB - : MUH-GA20VB -E1E1PERFORMANCE DATAHEAT operation (230V)MSC-GA25VB - : MUH-GA25VB -E1E1OUTDOOR WB(:)INDOOR-10 -5 0 5 10 15 20DB(

Seite 15 - COOL operation (230V)

22TROUBLESHOOTING103. Troubleshooting procedure1) First, check if the OPERATION INDICATOR lamp on the indoor unit is flashing on and off to indicate a

Seite 16

2310-2. Instruction of troubleshootingStartIndoor unit operates.Outdoor unit doesn't operate.Indoor unit doesn't receive the signal from re

Seite 17

24AACheck of outdoor unitCompressor and/or outdoor fan motor doesn’t operate.YesCompressor doesn't operate.YesYesIs there 230V AC between 3 on th

Seite 18

25BB Check of outdoor unitDoes compressor stop?NoYesIs there 230V AC between 3 on thecompressor contactor (52C) and N on the outdoor terminal block (

Seite 19

26DDHow to check mis-wiring and serial signal errorSerial signal error is indicated.(0.5-sec. ON, 0.5-sec. OFF)1. Turn OFF the power supply(indoor/out

Seite 20

27EE Check of outdoor thermistorMeasure resistance between CN 661 1 and 2.NoYesReplace the thermistor.Defrost thermistor (RT61)Reconnect CN661.Turn O

Seite 21 - HEAT operation (230V)

28MUH-GA20VB -MUH-GA25VB -MUH-GA35VB -Outdoor deicer P.C. boardE1E1E1CN711Outdoor fan motor 230V ACCN721R.V. coil230V ACF61Fuse2A/250V}}CN661 1-2De

Seite 22 - SERVICE FUNCTIONS

29DISASSEMBLY INSTRUCTIONS11MUH-GA20VB - MUH-GA25VB - MUH-GA35VB -OUTDOOR UNITE1E1E1OPERATING PROCEDURE PHOTOS1. Removing the cabinet(1) Remove the sc

Seite 23

3RefrigerationoilRefrigerantNew refrigerantR410AHFC-32: HFC-125 (50%:50%)Pseudo-azeotropic refrigerantNot includedA1/A172.6-51.41.55764Non combustible

Seite 24 - Check of outdoor unit

303. Removing the propeller and the outdoor fan motor(1) Remove the cabinet. (Refer to 1.)(2) Remove the propeller nut.(3) Remove the propeller.NOTE :

Seite 25

31OPERATING PROCEDURE PHOTOS4. Removing the compressor(1) Remove the cabinet. (Refer to 1.)(2) Remove the relay panel.(3) Remove the soundproof felt.(

Seite 26

32PARTS LIST1222352211(W) 1512-1. OUTDOOR UNIT STRUCTURAL PARTSMUH-GA20VB - MUH-GA25VB - MUH-GA35VB -E1E1E1417 14192018136 78910 11121623(W) This f

Seite 27 - Check of outdoor thermistor

33Part numbers that are circled are not shown in the illustration.123456789101112131415161718192021222324252627282930313233E02 904 630E02 905 630E

Seite 28

34OB387-2.qxp 05.2.21 10:03 AM Page 34

Seite 29 - DISASSEMBLY INSTRUCTIONS

35OB387-2.qxp 05.2.21 10:03 AM Page 35

Seite 30 - OPERATING PROCEDURE PHOTOS

CCCopyright 2005 MITSUBISHI ELECTRIC ENGINEERING CO.,LTDDistributed in Feb. 2005. No.OB387 6Made in JapanNew publication, effective Feb. 2005Specifica

Seite 31

42.Refrigerant piping1 SpecificationsUse the refrigerant pipes that meet the following specifications.• Use a copper pipe or a copper-alloy seamless p

Seite 32 - PARTS LIST

5R410APipe diametermm6.359.521722Dimension of flare nutR2217222 Flaring work and flare nutFlaring work for R410A pipe differs from that for R22 pipe.F

Seite 33

6PART NAMES AND FUNCTIONS2( )Air inletAir outletDrain outletPipingDrain hoseback : MUH-GA20VBback and side : MUH-GA2

Seite 34

7NOISE CRITERIA CURVES490807060504030201063 125 250 500 1000 2000 4000 8000APPROXIMATETERESHOLD OFHEARING FORCONTINUOUSNOISENC-60NC-50NC-40NC-30NC-20N

Seite 35

8OUTLINES AND DIMENSIONS51069800302.5500 Bolt pitch for installation15022.3Handle550280164.599.5170.523Service panelService port285344.544400Air inAir

Seite 36

9WIRING DIAGRAM6MODELS WIRING DIAGRAMSYMBOLT61TB1,TB221S452CSYMBOLMFNR61RT61SR61,SR62SYMBOLC1C65DSARF61MCNAMENAME NAMECOMPRESSOR CAPACITOROUTDOOR FAN